Supported Devices & Compatibility Matrix¶
This document tracks which Hitachi devices have been tested with this integration and what features work for each configuration.
If you're using this integration, please contribute by adding your device configuration below! This helps the community understand what works and what doesn't.
How to Contribute Your Testing Results¶
- Fork this repository or edit this file directly (click the pencil icon on GitHub)
- Add your device to the appropriate table below
- Fill in all columns with your test results
- Submit a pull request or create an issue with your findings
Quick Reference: Device Types¶
Based on the CSNet Manager system, devices are categorized by Unit Model and Zone Types:
Unit Models¶
- Yutaki S - Standard model
- Yutaki SC - Comfort model
- Yutaki S80 - 80°C high-temperature model
- Yutaki M - Monobloc model
- Yutaki SC Lite - Lite version
- Yutampo - Specific regional model
Zone Types¶
- Zone 1 (C1 Air) - Air circuit 1 (room thermostats)
- Zone 2 (C2 Air) - Air circuit 2 (room thermostats)
- Zone 3 (DHW) - Domestic Hot Water
- Zone 5 (C1 Water) - Water circuit 1 (floor heating, radiators)
Compatibility Matrix¶
Legend¶
- ✅ Working - Feature fully functional
- ⚠️ Partial - Feature works with limitations (see notes)
- ❌ Not Working - Feature not functional
- ➖ N/A - Not applicable for this configuration
- ❓ Unknown - Not tested yet
Yutaki S Models¶
Configuration Details¶
| Tester | Unit Model | Firmware | Heat Circuits | Thermostats | DHW | Integration Version | Last Updated |
|---|---|---|---|---|---|---|---|
| @mmornati | Yutaki S | H-0302 | 2 (C1, C2 - Floor Heating) | 2 (1 per floor) | ➖ N/A | Latest | 2025-10-24 |
| @Aparenty-1977 | Yutaki S2 | ❓ Unknown | ✅ | ❓ Unknown | ✅ Yutampo | Latest | 2025-10-26 |
| Add your config | | | | | | | |
Feature Compatibility¶
| Tester | Climate Control | Temperature Set | HVAC Modes | Preset Modes | DHW Control | Silent Mode | Fan Control | Alarm Monitor | OTC Support | Multi-Zone |
|---|---|---|---|---|---|---|---|---|---|---|
| @mmornati | ✅ | ✅ | ✅ Heat/Cool/Auto/Off | ✅ Eco/Comfort | ➖ N/A | ❓ Unknown | ➖ N/A | ❓ Unknown | ✅ | ✅ 2 zones/2 thermostats |
| @Aparenty-1977 | ✅ | ✅ | ❓ Unknown | ❓ Unknown | ✅ Yutampo | ❓ Unknown | ❓ Not tested | ❓ Not tested | ❓ Unknown | ❓ Unknown |
| Add your results |
Known Issues & Notes¶
| Tester | Issues / Notes |
|---|---|
| @mmornati | - Working perfectly: C1 and C2 circuits for floor heating (1 circuit per floor) - Thermostats: 2 separate room thermostats, one per floor - - Temperature control: Responsive, range 8-55°C for heating - Sensors: All system sensors reporting correctly |
| Add your notes |
Yutaki SC Models¶
Configuration Details¶
| Tester | Unit Model | Firmware | Heat Circuits | Thermostats | DHW | Integration Version | Last Updated |
|---|---|---|---|---|---|---|---|
| Add your config | Yutaki SC |
Feature Compatibility¶
| Tester | Climate Control | Temperature Set | HVAC Modes | Preset Modes | DHW Control | Silent Mode | Fan Control | Alarm Monitor | OTC Support | Multi-Zone |
|---|---|---|---|---|---|---|---|---|---|---|
| Add your results |
Known Issues & Notes¶
| Tester | Issues / Notes |
|---|---|
| Add your notes |
Yutaki S80 Models¶
Configuration Details¶
| Tester | Unit Model | Firmware | Heat Circuits | Thermostats | DHW | Integration Version | Last Updated |
|---|---|---|---|---|---|---|---|
| Add your config | Yutaki S80 |
Feature Compatibility¶
| Tester | Climate Control | Temperature Set | HVAC Modes | Preset Modes | DHW Control | Silent Mode | Fan Control | Alarm Monitor | OTC Support | Multi-Zone |
|---|---|---|---|---|---|---|---|---|---|---|
| Add your results |
Known Issues & Notes¶
| Tester | Issues / Notes |
|---|---|
| Add your notes |
Yutaki M Models¶
Configuration Details¶
| Tester | Unit Model | Firmware | Heat Circuits | Thermostats | DHW | Integration Version | Last Updated |
|---|---|---|---|---|---|---|---|
| Add your config | Yutaki M |
Feature Compatibility¶
| Tester | Climate Control | Temperature Set | HVAC Modes | Preset Modes | DHW Control | Silent Mode | Fan Control | Alarm Monitor | OTC Support | Multi-Zone |
|---|---|---|---|---|---|---|---|---|---|---|
| Add your results |
Known Issues & Notes¶
| Tester | Issues / Notes |
|---|---|
| Add your notes |
Yutaki SC Lite Models¶
Configuration Details¶
| Tester | Unit Model | Firmware | Heat Circuits | Thermostats | DHW | Integration Version | Last Updated |
|---|---|---|---|---|---|---|---|
| Add your config | Yutaki SC Lite |
Feature Compatibility¶
| Tester | Climate Control | Temperature Set | HVAC Modes | Preset Modes | DHW Control | Silent Mode | Fan Control | Alarm Monitor | OTC Support | Multi-Zone |
|---|---|---|---|---|---|---|---|---|---|---|
| Add your results |
Known Issues & Notes¶
| Tester | Issues / Notes |
|---|---|
| Add your notes |
Yutampo Models¶
Configuration Details¶
| Tester | Unit Model | Firmware | Heat Circuits | Thermostats | DHW | Integration Version | Last Updated |
|---|---|---|---|---|---|---|---|
| Add your config | Yutampo |
Feature Compatibility¶
| Tester | Climate Control | Temperature Set | HVAC Modes | Preset Modes | DHW Control | Silent Mode | Fan Control | Alarm Monitor | OTC Support | Multi-Zone |
|---|---|---|---|---|---|---|---|---|---|---|
| Add your results |
Known Issues & Notes¶
| Tester | Issues / Notes |
|---|---|
| Add your notes |
Fan Coil Systems¶
These systems support fan speed control (off, low, medium, auto) instead of silent mode.
Configuration Details¶
| Tester | Unit Model | Firmware | Heat Circuits | Fan Coils | DHW | Integration Version | Last Updated |
|---|---|---|---|---|---|---|---|
| Add your config |
Feature Compatibility¶
| Tester | Climate Control | Temperature Set | HVAC Modes | Preset Modes | DHW Control | Fan Speed Control | Alarm Monitor | OTC Support | Multi-Zone |
|---|---|---|---|---|---|---|---|---|---|
| Add your results | ✅ Off/Low/Med/Auto |
Known Issues & Notes¶
| Tester | Issues / Notes |
|---|---|
| Add your notes |
Other Hitachi Models¶
If your model isn't listed above, please add it here!
Configuration Details¶
| Tester | Unit Model | Firmware | Heat Circuits | Thermostats | DHW | Integration Version | Last Updated |
|---|---|---|---|---|---|---|---|
| Add your config | Your Model |
Feature Compatibility¶
| Tester | Climate Control | Temperature Set | HVAC Modes | Preset Modes | DHW Control | Silent Mode | Fan Control | Alarm Monitor | OTC Support | Multi-Zone |
|---|---|---|---|---|---|---|---|---|---|---|
| Add your results |
Known Issues & Notes¶
| Tester | Issues / Notes |
|---|---|
| Add your notes |
Feature Descriptions¶
Climate Control¶
Full control of your heat pump system through Home Assistant climate entities. One climate entity per zone/thermostat.
Temperature Set¶
Ability to set target temperature. Range varies by mode and configuration (typically 8-55°C).
HVAC Modes¶
- Heat - Heating mode
- Cool - Cooling mode (if supported by your system)
- Auto - Automatic heating/cooling based on temperature
- Off - System off
Preset Modes¶
- Comfort - Normal comfort temperature
- Eco - Energy-saving mode with reduced temperature
DHW Control¶
Control of Domestic Hot Water heater with modes: - Off - DHW off - Eco - Standard DHW heating - Performance - Boost mode for faster heating
Silent Mode¶
Reduces outdoor unit noise (not available on fan coil systems).
Fan Control¶
For fan coil systems only. Speeds: Off, Low, Medium, Auto.
Alarm Monitor¶
Displays alarm codes and messages from the system with persistent notifications.
OTC Support¶
Outdoor Temperature Compensation - automatic adjustment based on outdoor temperature.
Multi-Zone¶
Support for multiple heating circuits (C1, C2) and multiple room thermostats.
Additional Sensors¶
The integration provides additional sensors for system monitoring:
Device-Level Sensors¶
- Current temperature
- Target temperature
- Operating mode
- On/Off status
- Alarm status
- WiFi signal strength
- Connectivity status
- Last communication timestamp
Installation-Level Sensors (if supported)¶
- Pump speed
- Water flow
- Water inlet/outlet temperature
- Water pressure
- Gas/liquid temperature
- Defrost status
- Mix valve position
- Outdoor temperature
- Weather temperature (from cloud)
- LCD software version
- Central control configuration
- System configuration bits
- OTC type settings
How to Find Your Device Information¶
Finding Your Unit Model¶
- Open the CSNet Manager app or website
- Go to Settings → System Information
- Look for Unit Model field
Finding Your Firmware Version¶
- In Home Assistant, go to Settings → Devices & Services
- Find your Hitachi device
- Look at device information for firmware version
Finding Your Zone Configuration¶
- In the CSNet Manager app, check how many thermostats/zones are configured
- In Home Assistant, count the number of climate entities created
- Check if you have a DHW (water heater) entity
Troubleshooting & Debug Information¶
If you're experiencing issues:
-
Enable debug logging in
configuration.yaml: -
Capture the elements response from CSNet Manager:
- Open browser Developer Tools (F12)
- Navigate to CSNet Manager website
- Go to Network tab
- Find the
elementsAPI call -
Copy the JSON response
-
Report the issue on GitHub Issues with:
- Your device configuration
- Debug logs
- Elements JSON response (redact personal info)
Contributing¶
Your feedback is valuable! Even if everything works perfectly, please add your configuration to help others with similar setups.
Quick Contribution Steps:¶
- Click the Edit button (pencil icon) on this file in GitHub
- Add your device to the appropriate table
- Fill in your test results
- Submit a pull request with description: "Add device compatibility: [Your Model]"
What to Include:¶
- ✅ DO include firmware version
- ✅ DO note specific configuration (number of circuits, thermostats)
- ✅ DO mention any workarounds you found
- ✅ DO update integration version
- ❌ DON'T include personal information (addresses, names, etc.)
Discussion¶
Join the discussion about device compatibility: - Discussion #21 - Mode and preset mappings - GitHub Discussions
License¶
This document is part of the home-assistant-csnet-home project and is licensed under the Apache License 2.0.
Last Updated: 2025-01-24 Document Version: 1.0